Features and Benefits

GreenWheel® ERV

  • Non-migrating desiccant is impregnated within the structure
  • 4A molecular sieve desiccant
  • Synthetic media resists corrosion
  • Flute geometry reduces cross contamination
  • Transfers both sensible and latent heat
  • Can be cleaned with a hose or steam cleaner

Quality Components

  • Full contact brush seal
  • Internal sealed roller bearings
  • 16 Ga. galvanized sheet metal frame

GreenWheel® Energy Recovery Ventilator

Marvair GreenWheel

The Marvair® GreenWheel® ERV is a total energy (both sensible and latent) wheel that reduces both construction and operating cost while ventilating the classroom to ASHRAE 62-1999 requirements. The use of the GreenWheel ERV reduces the energy load of the outside air. Exhausting stale, inside air keeps indoor pollutants and harmful gases to a minimum. The Marvair GreenWheel ERV has been tested and certified according to ARI Standard 1060.

How It Works

During the summer, cool dry air from the classroom is exhausted through the GreenWheel® ERV to the outside. As the air passes through the rotating wheel, the desiccant becomes cooler and drier.  Simultaneously, hot humid air is being pulled across the rotating wheel. The cool, dry desiccant absorbs moisture and heat from the incoming air. The cooler, drier air is mixed with the return air from the classroom and distributed throughout the room.

In the winter, warm moist air is exhausted through the GreenWheel ERV to the outside. As the air passes through the rotating wheel, the desiccant becomes warmer and absorbs moisture. Simultaneously, cold dry air is being pulled across the rotating wheel. The cold, dry air absorbs heat and moisture from the desiccant.  The warmed air is mixed with the return air from the classroom and distributed throughout the room.

Quality Components

The GreenWheel® ERV cassette consists of the wheel, two blowers and the drive motor and belt. The two blowers simultaneously pull fresh air from outside and exhaust air from the classroom through the rotating wheel. The air streams are separated by an insulated partition so that the incoming fresh air is not mixed with the exhaust air. Two variable speed blowers ensure that up to 450 CFM of outside air can be brought into the room and the indoor air is properly exhausted. Variable speed blowers permit that the desired quantity of outside air is delivered into the room. Optional independent exhaust air blower control allows positive pressurization of the classroom, i.e., more outside air can be introduced through the GreenWheel ERV than is exhausted.

Marvair GreenWheel Summer Operation

Marvair GreenWheel Winter Operation